100-240VAC (Range: 90-264Vac)
9.0-36V
0.1-4.0A
C8 or C6 or C14 or attached with AC cable
UL, CCC, FCC, UKCA, CE, ROHS, REACH,RCM, SAA, C-TICK, EAC, S-mark
IEC62368 EN62368 UL62368 GB4706 GB4943 J62368
EN55032 class B/EN61000 GB17625 FCC Part15
black or white optional
5.5*2.1mm, 4.0*1.7mm, 3.5*1.35mm, USB C etc...
0.1W.
With Over-current, over-voltage, short-circuit, over-temperature protection to protect circuit.
The input power shall be less than 0.1W at 115 or 230Vac input
Measured at 115Vac or 230Vac input voltage, 100% load ,The efficiency is 84% Min..
0℃ to +40℃、 10%RH to 90%RH、
Storage Temperature and Relative Humidity、
-25℃ to +70℃、5%RH to 95%RH non-condensing
1M for wall mount type and 0.76M for desktop as above described. Test times for each 1 times, a total of 6 times; The horizontal surface consists of hardwood at least 13mm thick,the plug can be bend, and scratch, but the structure should not be damaged, and can work normally.
100MΩ Min. between primary to secondary add 500Vdc test voltage.
Measured at 115Vac or 230Vac input voltage, Average efficiency can reach energy star VI (87.77%) standard.
Primary to Secondary: 1500Vac /10mA Max / 60S (when safety testing);
Primary to Secondary:1800Vac /5mA Max / 3S (when production).
3.5mA maximum, at nominal AC input voltage and frequency
EMS Standards;
SURGE LEVEL: ±1KV(DM), ±2KV(CM) Standards IEC61000-4-5.
Note:Power supply is not damaged, allowing restart.
2 hours at 40°C maximum, Normal input voltage, rated load.
When the power supply is operating within the limits of this specification the MTBF shall be at least 50000 hours at 25℃ (MIL-HDBK-217F).
10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth: 3.5mm) for 1Hour for each of the perpendicular axes X, Y, Z.